Print-Friendly  

This is a test that uses orange dye (fluorescein) and a blue light to detect foreign bodies in the eye. This test can also detect damage to the cornea. The cornea is the outer surface of the eye.

A piece of blotting paper containing the dye is touched to the surface of your eye. You are asked to blink. Blinking spreads the dye and coats the tear film covering the surface of the cornea. The tear film contains water, oil, and mucus to protect and lubricate the eye.

The health care provider then shines a blue light at your eye. Any problems on the surface of the cornea will be stained by the dye and appear green under the blue light.

The health care provider can determine the location and likely cause of the cornea problem depending on the size, location, and shape of the staining.

I Would Like to Learn About:

  • How the Test is Performed

    A piece of blotting paper containing the dye is touched to the surface of your eye. You are asked to blink. Blinking spreads the dye and coats the tear film covering the surface of the cornea. The tear film contains water, oil, and mucus to protect and lubricate the eye.

    The health care provider then shines a blue light at your eye. Any problems on the surface of the cornea will be stained by the dye and appear green under the blue light.

    The health care provider can determine the location and likely cause of the cornea problem depending on the size, location, and shape of the staining.

  • How to Prepare for the Test

    You will need to remove your eyeglasses or contact lenses before the test.

  • How the Test Will Feel

    If eyes are extremely dry, the blotting paper may be slightly scratchy. The dye may cause a mild and brief stinging sensation.

  • Why the Test is Performed

    This test is useful in finding superficial scratches or other problems with the surface of the cornea. It can also help reveal foreign bodies on the eye surface. It can be used after contacts are prescribed to determine if there is irritation of the surface of the cornea.

  • Normal Results

    If the test result is normal, the dye remains in the tear film on the surface of the eye and does not stick to the eye itself.

  • What Abnormal Results Mean

    • Abnormal tear production (dry eye)
    • Corneal abrasion (a scratch on the surface of the cornea)
    • Foreign bodies, such as eyelashes or dust (see eye - foreign object in)
    • Infection
    • Injury or trauma
    • Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

    Additional conditions under which the test may be performed:

    • Blocked tear duct
  • Risks

    If the fluorescein touches the skin surface, there may be a slight, brief, discoloration.

  • Considerations

    This test is very useful for detecting injuries or abnormalities on the surface of the cornea.

Related Information

  Corneal injuryEye - foreign obje...Blocked tear duct...    

References

Knoop KJ, Dennis WR, Hedges JR. Ophthalmologic procedures. In: Roberts JR, Hedges JR, eds. Clinical Procedures in Emergency Medicine. 5th ed. Philadelphia, PA: Elsevier Saunders; 2009:chap 63.

BACK TO TOP 

Review Date: 1/22/2013  

Reviewed By: Linda J. Vorvick, MD, Medical Director and Director of Didactic Curriculum, MEDEX Northwest Division of Physician Assistant Studies, Department of Family Medicine, UW Medicine, School of Medicine, University of Washington. Also reviewed by A.D.A.M. Health Solutions, Ebix, Inc., Editorial Team: David Zieve, MD, MHA, David R. Eltz, Stephanie Slon, and Nissi Wang.

The information provided herein should not be used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed medical professional should be consulted for diagnosis and treatment of any and all medical conditions. Call 911 for all medical emergencies. Links to other sites are provided for information only -- they do not constitute endorsements of those other sites. © 1997- A.D.A.M., Inc. Any duplication or distribution of the information contained herein is strictly prohibited.

adam.com

 
A.D.A.M. content is best viewed in IE9 or above, Fire Fox and Google Chrome browser.